日本法科学技術学会

メインページ
当学会について
学会誌
執筆要領
投稿規定
タイトルリスト
賛助会員
[English]
[会員用ページ]
日本鑑識科学技術学会誌 
Volume 6, Number 2, (2002)

  • 有機絶縁物のトラッキング現象と火災...木下勝博
  • モノクローナル抗体を用いた改良混合凝集法によるABO式血液型検査法...淀谷順一郎,五十嵐一雄
  • 陰毛の個人内における形態学的変動...岩本良二,太田奈穂樹,相場 伸,相川雄大,棟方栄治
  • アシル誘導体を用いたLC/MSによる毛髪中メタンフェタミンとアンフェタミンの分析...西田憲市,成原政治,堤 一博,伊東晋治
  • 神経ガス分解物の固相抽出前処理法...片岡美江子,瀬戸康雄
  • A New Procedure for the Multiplex PCR Amplification of TH01, CSF1PO and TPOX Loci with Small Amplicon Lengths...藤井宏治,千住弘明,吉田日南子,佐藤 元,笠井賢太郎
  • Evaluation of Morphometric Matching for the Identification of Caucasian Faces from Blurred Images...厚地 将,野口加寿美,窪田 聡,今泉和彦,櫻田宏一,吉野峰生,Natalie L. Fraser,C. David L. Thomas,John G. Clement
  • ニンヒドリン-酢酸溶液およびスプレーガンによる潜在指紋の検出...石澤不二雄,石綿鉄也,大串 猛,高村保夫,河野正一,大高一男




  • Volume 6, Number 2, pp.65-83 (2002)
    有機絶縁物のトラッキング現象と火災
    木下勝博
    Tracking phenomenon, to put it plainly, is the phenomenon to form the car- bonized electrical track and lose insulation in the part with potential difference on the surface of insulating materials. Tracking resistance means the difficulty occuring the tracking phenomenon of the organic insulation materials. Studies on the track- ing phenomenon and the method of evaluating tracking resistance has been often reported on so far. But, there are only a few comprehensive researches and commen- taries which include tracking phenomenon and the fire which occurs by the tracking phenomenon. Hence, I decided to explain tracking phenomenon of the organic in- sulating materials and the phenomenon that developed concerning the fire which de- velops and is called, tracking fire. Tracking phenomenon is discussed first. Next, cases of tracking fire in electric wiring and the wiring utensil and the studies on the cause of tracking fire are explained. Furthermore, prevention of tracking fire and fu- ture problems are also discussed.
    Keywords...Tracking phenomenon, Tracking fire, Carbonized electrical track, Tracking resistance

    Volume 6, Number 2, pp.85-97 (2002)
    モノクローナル抗体を用いた改良混合凝集法によるABO式血液型検査法
    淀谷順一郎,五十嵐一雄
    This study demonstrates the causes and the prevention measure of the non- specific adherence phenomenon observed in the mixed cell agglutination reaction (MCAR) method using monoclonal antibodies for ABO blood grouping from vari- ous kinds of forensic samples. The phenomenon could be suppressed by the addition of both a milk protein (6% Block-Ace) and a detergent (0.3% Tween 20) into the antibody reagents, so that the causes of the phenomenon were likely to be both the electric charge potential effect and the physical absorption of the monoclonal an- tibodies. In this modified MCAR method, the operation time could be shortened to be about 2/3 of that of the conventional method.
    Keywords...ABO blood groups, MCAR, Milk protein, Detergent

    Volume 6, Number 2, pp.99-108 (2002)
    陰毛の個人内における形態学的変動
    岩本良二,太田奈穂樹,相場 伸,相川雄大,棟方栄治
    This paper presents a study of the intra-individual variation of pubic hairs. Seventy pubic hairs were pulled from seven sites around the outer genital area of each of five Japanese males; sixty were obtained from six sites on each of four Japanese females, and fifty from six sites on one additional Japanese female. These hairs were examined with respect to twenty-two morphological characteristics. These morphological data were studied in relation to each site and analyzed by the statistical method of cluster analysis.
    It appeared that a pubic hair's length, luster, diameter, medullary index, disease and scale damage bore some relation to the site from which it was obtained. Dendrograms produced through the cluster analysis showed a hierarchy of similarities among all pairs of pubic hairs. Similar hairs were placed together into several large or small groups within the same person. Some groups contained pubic hairs from many sites, whereas others were almost exclusively from only one site. This means that some sites have different characteristics from other sites. Pubic hairs obtained from the penis area, scrotum and labium majus area showed greater dissimilarity than other sites within the same person.
    Therefore, in forensic hair comparison, known pubic hair samples should be obtained from many different sites. For males, at least thirty-five pubic hairs should be collected from seven sites (center, left and right abdomen; upper, left and right area surrounding the penis; and scrotum). For females, at least thirty pubic hairs should be collected from six sites (center, left and right abdomen; mons pubis; left and right labium majus).
    Keywords...Forensic hair comparison, Pubic hair, Intra-individual variation, Cluster analysis

    Volume 6, Number 2, pp.109-115 (2002)
    アシル誘導体を用いたLC/MSによる毛髪中メタンフェタミンとアンフェタミンの分析
    西田憲市,成原政治,堤 一博,伊東晋治
    For the high sensitive and selective detection of methamphetamine (MA) and amphetamine (AP) in abusers' hair, we examined and analyzed acylated derivatives of MA and AP by high-performance liquid chromatography-electrospray ionization mass spectrometry. MA and AP were derivatized by trifluoroacetic acid anhydride (TFAA) or pentafluoropropionic acid anhydride (PFPA) , as the general acylating reagents. Acylated derivatives were stabilized at least one week in methanol (sample solution) and until 4 hours at 40°C in methanol containing aqueous buffer solution (eluent solution). In both cases of derivatizaton by treatment with TFAA or PFPA, the calibration curves were linear up to at least 200 ng for MA and AP, and the detection limits were 10 pg for MA and 100 pg for AP, respectively, in the selected ion monitoring mode. This method could be successfully applied to the MA abusers' hair samples.
    Keywords...Methamphetamine, Amphetamine, Acylation, LC/MS, Hair analysis

    Volume 6, Number 2, pp.117-127 (2002)
    神経ガス分解物の固相抽出前処理法
    片岡美江子,瀬戸康雄
    The pretreatment method using solid phase extraction (SPE) was investigated for the determination of nerve gas hydrolysis products by gas chromatography-mass spectrometry after tert.-butyldimethylsilyl (TBDMS) derivatization. Various pretreatment conditions using six SPE cartridges [three strong anion exchanger (SAX) , one weak anion exchanger, one reversed phase and one mixed mode] were examined for the clean-up of methylphosphonic acid (MPA) , ethyl-, isopropyl- and pinacolylmethylphosphonic acid (EMPA, IMPA and PMPA), with regard to recovery from aqueous solution. Within them, optimized pretreatment method using a Bond Elut SAX cartridge containing 500 mg solid phase of fluoride form was established. After sample loading the cartridge was washed with water and retained methylphosphonates were eluted from the cartridge with 5ml of 3% (v/v) ammonia in methanol. The established method was applied to the pretreatment of various kinds of aqueous samples such as aqueous soil extract, sea water and beverages, and the dramatically improved yields of TBDMS derivatives were obtained, compared with those without SPE pretreatment.
    Keywords...Solid phase extraction, Alkyl methylphosphonate, Methylphosphonic acid, tert.-Butyldimethylsilylation, GC-MS

    Volume 6, Number 2, pp.129-134 (2002)
    A New Procedure for the Multiplex PCR Amplification of TH01, CSF1PO and TPOX Loci with Small Amplicon Lengths
    藤井宏治,千住弘明,吉田日南子,佐藤 元,笠井賢太郎
    We describe a new procedure for the multiplex PCR amplification of the three short tandem repeat (STR) loci; TH01, CSF1PO and TPOX with small amplicon lengths (the Small TCT Multiplex). The accuracy of the Small TCT Multiplex was verified by typing 100 Japanese samples that had been previously typed using an AmpFlSTR Green I PCR amplification kit (Green I Kit). The results using the Small TCT Multiplex were consistent with those obtained by the Green I Kit. STR typing using the Small TCT Multiplex was examined from 36 bloodstain samples that had been left for 1 to 25 years at room temperature and compared to that using the Green I Kit. The Small TCT Multiplex was superior to the Green I Kit for STR typing especially in the case of bloodstain samples that had aged for more than 8 years.
    Keywords...TH01, CSF1PO, TPOX, Multiplex PCR amplification, Degraded DNA

    Volume 6, Number 2, pp.135-138 (2002)
    Evaluation of Morphometric Matching for the Identification of Caucasian Faces from Blurred Images
    厚地 将,野口加寿美,窪田 聡,今泉和彦,櫻田宏一,吉野峰生,Natalie L. Fraser,C. David L. Thomas,John G. Clement
    The reliability of the morphometric matching method for identifying the blurred images of Caucasian faces was examined experimentally using a computer- assisted facial image identification system. For evaluating the match of the.3D and 2D facial images in the same person (a match), the 3D facial image obtained from 10 subjects was compared to the 2D oblique facial image of the same subject ten times, yielding 100 superimpositions. In the case of different persons (non-matching), the 3D facial images of 10 subjects were each compared to the 2D facial images of other 9 subjects, yielding 90 superimpositions. As a matching criterion, the sum of the values of the average perpendicular difference of the facial outlines and the average point-to-point difference between the corresponding landmarks was used (abbr.: average difference).
    The range of the average difference was 3.6-6.3 mm for the matching person and 5.8-15.3 mm for non-matching persons, respectively. The average difference and percentage error at the FP/FN crossover point were 6.0 mm and 3.2 percent. In this experiment, it was concluded that the morphometric matching method would be applicable to the identification of blurred images of Caucasian faces.
    Keywords...Personal identification, 3D Physiognomy, Morphometric matching, Caucasian face, Blurred image

    Volume 6, Number 2, pp.139-146 (2002)
    ニンヒドリン-酢酸溶液およびスプレーガンによる潜在指紋の検出
    石澤不二雄,石綿鉄也,大串 猛,高村保夫,河野正一,大高一男
    Two methods for developing latent fingerprints were examined by use of ninhydrin-acetic acid solution and spray gun.
    In one method, latent fingerprints were developed without heating by ninhydrin-acetic acid solution which contains 10 vol% of acetic acid and 90% of ninhydrin solution. The solution was brushed on paper, then it was enclosed in a plastic bag after volatilization of the solvent. Fingerprints were developed within 30 minutes without heating. This method was found to be useful for the development of latent finger-prints where heating devices such as an iron could not be used.
    In another method, latent fingerprints were developed by spraying gold powder on objects with a portable gas cylinder. Gold powder is the alloy of copper and zinc. Clear fingerprints were obtained because a brush was not required to develop them. This spray gun method could be applicable to all objects on which latent fingerprints were developed by the usual powder method, and was especially effective on oil-prints.
    Keywords...Latent fingerprint, Ninhydrin, Acetic acid, Gold powder, Spray gun


    日本法科学技術学会 office@houkagaku.org